Data acquisition unit
Ceramic

Data acquisition unit

Portable Recording
Small unit size and multiple functions
Support multiple cable buses, multiple types of instruments
Enables strong cable docking capability
Clear and complete knowledge function
Easier operation

Description

 

The portable data acquisition system is composed of a 2U portable waterproof case and a laptop computer. It can complete downhole instrumentation.

It can supply DC power to the downhole instrument, communicate with the downhole instrument and perform data acquisition, depth and tension acquisition. It is truly portable as it communicates with the laptop through the USB interface to complete the logging operation. The small size of the unit has many functions: it can support many cable buses and many types of instruments; it has excellent cable equalization compensation circuit and algorithm, which makes the ability of mating cables strong; the indication function is clear and perfect, and the operation is easier; the full range of working power supply makes the application quite convenient.

 

Tank Indicators

Physical parameter

Length

608.0mm(23.9″)
Width

565.5mm(22.2″)

Height

156.0mm(6.1〞)
Weight

12.5Kg(27.5lb)

 

Usage environment

Storage temperature: -10℃~+70℃

Operating temperature: 0℃~+60℃

Recommended temperature: +10℃~+50℃

 

Technical specifications

Working power: AC 100~240V (47~63Hz) or DC 140~343V;
Maximum power consumption: 240 watts
Communication cable: Single-core cable, signal and power multiplexing

 

Instrument power supply:

  1. Voltage DC 25-240V adjustable
  2. Current 40~500mA adjustable
  3. Power not more than 100W

 

Compatible data formats:

Pulse-type signals – positive, negative and both positive and negative at the same time.
The DDL-III’s 5.7129 Kbps zeroed Manchester code.
20.833 Kbps half-duplex non-zeroing Manchester code compatible.
WSCBUS bus. 300bps command, 50Kbps to 100Kbps AMI code. Communication rates above 50Kbps require high cable
transmission characteristics. Not all cables can transmit properly.

 

Supported Instruments:

DDL-III format transmission, pulse transmission production logging instrument.
WSCbus transmission for production logging instruments, dobby instruments, etc.
The type of instrumentation supported is largely determined by the logging software.

 

Tension signal:

Tension meter with analog signal output, range 0.25 V to 5 V.
Provides ±15 V power supply.

Data acquisition unit

Data acquisition unit

 

Depth Signal:

Quadrature signal incremental encoder. Supplied with +5V supply, reference ground is electrically isolated from system ground.

Depth range: -9999.9 ~ +99999. 9 meters or feet, metric inch system optional.

Logging speed: Fastest 3600 m / h, general 600 m / h
Depth sampling interval: Maximum 320 points/meter, where an optical encoder resolution greater than 640/m is required.
Output scale: 1∶20(50,100,200,500,1000)optional
Number of curves displayed: 1-400 Articles.
Display method: Curve and depth synchronized rollover.
Recording method: Hard disk, thermal plotting.
Communication Interface: USB interface, device